25 main power supply malfunction mazak. org/wfkdb/generador-direccion-belgica.


Z Drive:d2. com. Following alarm does not go: "394 ATC Controller Malfunction" What should I do? The machine is at stand still, cannot zero it in normal condition, only possible with interlock on. blown components on the SE-IO1 circuit board 3. Went a try to start spindle, the power stay in the same value. we have a 1999 QT-250 Mazak and we are getting this alarm. Would appreciate any help. Anyone know were can i find the manuals for this controllers or a description of the alarms. Lets explore what was done and what happend. Action call Mazak Service. Control power supply fuse blown. and another in the MR-J2 servo for the turret The T-Plus and newer you change them with power on. D. 24, 12, -12, 5 volts. You should see a terminal strip at the top and each terminal should be clearly marked as to which voltage it is. The power supply is behind the control boards in the back electrical cabinet. There are 5 possible reason for this alarm, but the machine is not giving me the reason, Just a number 21 alarm. Feb 2, 2024 · Skip to main content. TV . To restore the machine to normal operation May 27, 2011 · I restarted several times but the same result. I gather Oct 3, 2003 · 1) The power cable from the factory feeder switch to the machine main circuit breaker should have a sufficient sectional area to handle the electric power used. Alarms are disappearing after shutdown an main braker in OFF position for couple seconds. View and Download Mazak VTC-200B operating manual online. Mazak System/Drive 376 MAIN POWER TURNING OFF MALFUNCTION; 377 Configure a circuit to turn off EM2 or EM1 when the main circuit power supply is turned off to prevent an unexpected restart of the servo amplifier (drive unit). I'm getting this servo alarm and can't figure out how to clear it out. Jan 4, 2024 · Good morning, We have an issue with our Mazak Power master fusion 640t Recently, when we start the Mazak CNC machine, the following alarm appears: 22 FEEDBACK SYSTEM MALFUNCTION (1, 0, 0025) Then we replaced the 3. Make your Move to a New Mazak EZ Machine Today. $25. Obviously nothing much happens after this. Even so! When machine is braking in gear 2 never manage to stop. Nov 6, 2009 · Went to fire up the Nexus 410A-II when these two alarms pop up #212 Magazine Drum Malfunction & #302 ATC Arm Driver Malfunction X & Y will home out Z will not Machine is not abused and has very little run time, last program run, drilling and tapping 4 holes 1/2-13 We have a mazak Slant Turn 60N and we have been experiencing the same alarm on our machine, alarm "main supply power malfunction". Oct 11, 2012 · HEIDENHAIN Forum - HEIDENHAIN develops and manufactures linear encoders, angle encoder, rotary encoders, and CNC controls for rigorous positioning tasks. e. Do not remove the front cover and connector even when the power is OFF unless carrying out wiring work or periodic inspections. Our Mazak MTV 655/60 drive broke several weeks ago. this is the alarm on mazatrol controller 21 Drive unit power malfunction 1,0,&0023 alarm the new spindle amp is flashing F6 and 23 Apr 4, 2014 · Well as stated above, Im having trouble with our Mazak. I tried to reinitialize my machine (1988 QT 8 T2 Control). Aug 4, 2016 · Need Help!-alarm 22 feedback system malfunction (1,0,&0021) after initializing MAZAK; Need Help!-Mazak QT20 T1 - Alarm 55 - Fanuc spindle drive overload; Mazak QT20 Alarm; Need Help!-T32-3 System Malfunction Alarm 015 (2,9476) Need Help!-Mazak T32-3 Alarm 015 System Malfunction HCN eries Hrd et cge 6000 rpm spindle output/torque diagram HCN-6800, HCN-8800, HCN-10800 HCN-12800 Spindle rotation Arc movement on X and Y axes Jan 4, 2024 · We have an issue with our Mazak Power master fusion 640t Recently, when we start the Mazak CNC machine, the following alarm appears: 22 FEEDBACK SYSTEM MALFUNCTION (1, 0, 0025) Then we replaced the 3. It seems to happen after a couple of minutes of roughing on every part. His injury could have been avoided if there was good debriefing between him and the customer. doea not work. Perform routine maintenance on your Mazak machine to prevent alarm occurrences Ok-if I recall correctly a lot of the spindle controllers would latch the alarm in but if it was nothing serious you would have to to take the power off the controller by turning off the main machine breaker for 5 seconds or so. After the system boots, the following alarm appears: “22 Feedback System Malfunction (5,0,&0025)” According to the manual for Alarm 22 ( , , 25): Cause - This alarm implies decreases in the voltage of the Does this mean the power supply in the Vickers Computer, or the 24v power supply that runs the relays and opto-isolators? Thanks, Benjamin Jennings Similar Threads: Rebuild Hurco Power Supply w/ PC Power Supply VMX30; A2100 Diagnostic Errors after installnig new Power supply - tree VMC750; Need Help!-main power supply malfunction Hello guys. Though it hasn't time to really heat up. both are refurbished. So, I power the machine down and back up and still nothing on the power supply or drive. These drives won't be in the bank pictured above, but usually stand alone inside the electrical cabinet. This is probably basic knowledge but for some reason I'm having trouble finding a definitive answer. Social media usage statistics Dec 16, 2014 · we have a 1999 QT-250 Mazak and we are getting this alarm. Targeted search for over 3,800 companies ; Search among 500,000 products ; Social Media Ranking . Precautions include keeping hands away from controls after powering on, carefully checking programs and speeds, and not modifying parameters without understanding their functions. I cleaned the breaker connections and moved the breaker to a new spot on the bus bar. The alarm is always on the first process "facing" when the tool Jan 12, 2019 · On gear 2 machine get to 2200 rpm but deceleration to 0 rpm is taking over 10 second. Nov 3, 2021 · Hello. DriversEd72. From the next day, the following alarm appears: 22 FEEDBACK SYSTEM MALFUNCTION (2, 0, 0025) Apr 7, 2024 · PSU stands for Power Supply Unit. The machines transform productivity with innovative new technologies, from the 15" touch-panel MAZATROL SmoothSt CNC with full mechanical keyboard to the High-Damping Composite Casting (HDCC) base for better rigidity, less thermal distortion, longer tool life and Jun 28, 2016 · On startup the Power supply MDS-A-CV-260 shows and Alarm number 'A' for less than a second which means 'Contactor melt'. The book says power supply detected surge errors. Forum - The expert community . On this video you’ll see how to disable the spindle drive and its power supply to separate any spindle alarm and be able to test X , Z, turret and any other Alarm List for the Mazak INTEGREX 300/400-II For other Mazak alarm lists visit following pages. We replaced the main power supply and the spindle amplifier (which I assume is the drive unit) not sure though. It warns to thoroughly understand the manual and safety plates before operation to prevent injuries or damage. Jan 28, 2015 · I am using Mazak Quickturn 20 machine, machine is giving alarm - Alarm 21 Driver Unit Power Mulfunction Machine is normally working when started by spindle manually and on 300 rpm or higher, but when working when I stop the machine on 300 rpm or 800 rpm and then I start the machine again and it gives alarm 21. Dec 19, 2009 · I think that it worked after that, but, I honestly don't know if I indexed between the batteries, and when I got the malfunction. ) displayed in parentheses. 3. Since the high voltage is supplied to the main circuit connector while the power is ON or during Feb 25, 2018 · Had a VTC 20G in the mid 90's . Jul 12, 2010 · Supplier and product research . Note, supply votage has been Jan 12, 2012 · After checking transformer taps, and getting the phasing correct, I get alarm 25 main power supply malf on the screen. After turning power on, keep hands away from the keys, buttons, or switches of the operating panel until an initial display has been made. Mark. The e-brake goes off and it can't be Mar 14, 2013 · He also said to put the old power supply back in and send it in like that then return the new power supply for a credit. be/ReKk6EN4D6I Dec 16, 2014 · both are refurbished. Commonly know as IGBT's, these generation blocks are actually Darlington transistors. 0989-002. Before proceeding to the next operations, fully check that correct data has been entered and/or set. 2) Cables which must be laid on the floor must be protected from hot chips, by using rigid or other approved conduit, so that short-circuits will not occur. 00 shipping. Today we tried to install it but Im getting this alarm "Alarm 22 Amplifier not equipped" and on the drive leds it says AA. Overspeed (Analog) The temperature sensor is abnormal in the motor, or the temperature sensor cable is broken. Apr 10, 2013 · I can't see how a "coolant chiller" will give a spindle lube alarm, maybe a spindle oil chiller The oil chillers will shut down with high head pressure and give an alarm on the CNC if the air flow over the condenser coil drops due to fan quitting or things getting plugged up. Get the best deals on Mazak PLC Power Supplies when you shop the largest online selection at eBay. There was an instantaneous control power failure of 60ms or a. Free shipping on many items | Browse your favorite brands | affordable prices. . 6V battery, as per the alarm book instruction. ction Rcwiew the power supply. that did not work and we had a long list of alarms and no tool May 2, 2023 · Tip 1: Consult the Mazak Manuals. The document provides safety precautions for operating a MAZATROL FUSION 640T/MT/TE CNC machine. The document provides information about common CNC machine alarms, including: 1) Alarm Y03 means the NC believes an axis is not connected to the system, and to check servo amplifiers, DC link, and serial buss connections. After many trials, we found it does not get ready if the supply frequency is not in the range of 50 Hz +/- 2 Hz, i. Good luck with it, ToolCat I. (Main circuit g»ver switched on within 5s after it had switched off. I need the find the procedure for re-homing the turret. Get the best deals on Mazak Industrial Power Supplies when you shop the largest online selection at eBay. The machine starts up with an alarm 9 absolute position malfunction (&00000001, &0010) and alarm 72 servo warning (&0000009F, &0010) and if I wait a while the alarm 33 pops up with an e stop alarm at the same time or if I try and home the Jul 8, 2022 · Please help me i work with a mazak vtc 20 b and when i try to start spindle it show me a alarm "M41 SPINDLE MALFUNCTION 1 " the spindle drive show it "F4 32" The machine opening normal and it going to home position normally the problem occurs when i try to start spindle if anyone can help Check and remedy After turning NC power off, turn off the main circuit… Mazak Alarm 212 CHUCK OPEN/CLOSE SWITCH MALF. Apr 28, 2005 · The power supply unit is #1 on my list and order is as follows: #1 (power supply unit) MDS-A-CR-75 In alarm mode it flashes "E" In normal mode it reads "d" #2 (Spindle Control unit) MDS-B-SP-75 In alarm mode it flashes "F6" and "74" In normal mode it flashes "C6" slowly #3 (X axis Control unit) MDS-A-SVJ-06 In alarm mode it flashes "E7" and "F2" Feb 22, 2008 · This can help determine if the spindle is dragging down the supply such as 12 or -12 volts or the 24 Volts. We would have to cycle the power every morning and the alarm would clear. I’m trying to power up / home an Integrex 100 that’s been sitting a few months. It is the main hardware on a computer because, without it, a computer cannot boot. Power on when changed. Sep 15, 2011 · Hi guys. We had similar problem in year 2000, when Mitsubishi had launched MDS-B-CVE xxx Power Supply, which was not getting into ready mode at some customers. 25 above for the details of probable causes. 6 %âãÏÓ 2344 0 obj > endobj xref 2344 72 0000000016 00000 n 0000005376 00000 n 0000005630 00000 n 0000005762 00000 n 0000005914 00000 n 0000006058 00000 n 0000006726 00000 n 0000007136 00000 n 0000007297 00000 n 0000007472 00000 n 0000007538 00000 n 0000007709 00000 n 0000010181 00000 n 0000010901 00000 n 0000011058 00000 n 0000011132 00000 n 0000011283 00000 n 0000011386 00000 n To keep your facility running smoothly, Mazak's substantial, continuous investment in spare parts fulfillment ensures our fastest-possible reaction to the unexpected. You have to open the back plastic cover. 00: US $20. Thanks in advance. blown main power block(s) in the base of the drive. We have them turned on 140+ hours a week. I immediately contacted a CNC drive repair company and they had me check a few things. we're currently using mazak cnc lathe machine mazatrol pc fuzion 640T,until we encounter this kind of alarm. use a multimeter and test the test point on the supply at the top. Aug 24, 2018 · We have a mazak 5 axis with mazatrol matrix 2. Mar 20, 2023 · If the alarms are present after completing the steps outlined above, try the battery replacement procedure again without turning off the main power breaker. parameter sheets that came with machine. 31 SERVO MALFUNCTION 1. The Mazak SYNCREX Swiss-Type Production Turning Machines powers through high-speed production of small, precise parts. We purchased a used one on ebay from a guy with excellent reviews. SYNCREX. Power Cause vol is low. " Since the batteries are changed with power off, And I have corruption problems about half the time batteries are changed on these older controls. If so the supply is in overload. Together, we are the strongest Mastercam community on the web with over 56,000 members, and our online store offers a wide selection of training materials for all applications and skill levels. Power was mstored after the bus voltage had dropped to 2DDVDC. Shop by category See more 1PC Mitsubishi MAZAK Power Supply QX084 MELDAS Share | Add to Watchlist. Sep 8, 2008 · Does anyone has the manual of this controller. Thanks Apr 4, 2023 · This test was done on:1) Axis drive Mitsubishi MDS-EH-V2-80 (B73202), Mazak D80MA0244502) Spindle drive Mitsubishi MDS-EH-SP-480 (B73306), Mazak D80MA0245403 Apr 17, 2015 · On the drives I now have a C on the power supply unit and a 6C on the spindle drive unit. Mar 23, 2006 · I OPERATE MAZAK INTEGREX 200II SY with 640 fusion control. For alarm messages example 10 Detector Malfunction 1 (&00000001,&0007) I read the alarm as number 1 on the drive, and axis number 7 Oct 6, 2007 · I agree check your power supply voltages on the control. At the moment of closing the door, the machine doesn't spin. anyone know on how to eliminate this and what could be the cause? Mazak, Mitsubishi, Mazatrol > ALARM # 22 FEEDBACK SYSTEM MALFUNCTION (1,0,&0043) Oct 31, 2013 · Started this machine up this morning and this alarm came up. I am worried because the main screen doesnt show other alarms, but the y and x axis show alarms also F1 E7 on the mdsb-v1-110 and F2 E7 on mdsb-v2-1010. And now, I don’t know what I need to do! Help me!!!!! Sent from my iPhone using Tapatalk Laser CO2 Tubes, Diodes, RF and Power Supplies; P2X4A. A bad SE-PW power supply 2. Even Mazak support couldn't tell me. Action Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No. Hey I'm having issues with a Mazak Quick Turn 25 L. Feb 10, 2022 · I have a Mazak PFH - 5800 with Mazatrol 640M 80 tool unit cell, which is giving me fits. I looked in the cabinet and the drive is flashing 65. Beside the TPM that we did, even though not 100%, we would need to study on why the servo is always malfunction. So there are some serious hours on the 10y old electronics now. You can also look at the PD21 power supply. For a limited time, Mazak Capital Equipment Financing is offering 0% financing on select Mazak VC-Ez, VC-Ez X,QT-Ez and QTE models. 5, 05. Note: If the main power breaker is set to OFF and the batteries are not replaced properly, it will become impossible for the machine to operate. it should be 48 - 52 Hz. Nov 2, 2018 · Alarm 67 is indicating that the MDS-A/B/C-CV power supply unit has detected that either the R, S, or T line of the AC 200V has lost power, or is not connected. 7, 07 Sep 22, 2023 · I have a mazak 5-axis and it’s currently getting an alarm 33 servo malfunction 2 (&00000050, &0008). 6 vcd Mar 17, 2012 · Hi all, In our company, we have 14 Mazak machines FH6000, FH4800, VCN510, VTC200, QTN200 and so on. Dec 4, 2011 · The problem could be incoming power supply quality side. Free shipping Skip to main content. The inside of the units is charged, and can cause electric shocks. that did not work and we had a long list of alarms and no tool Feb 18, 2022 · Hi, I'm just getting into some Mazak gear for the first time. This will either be the result of something wrong with the voltage source (broken wire, poor connection, or an actual power problem) or something wrong internally to the power supply unit. Mazatrol 640T This program has performed an illegal operation and will be shut down Nov 14, 2015 · So, I go to the back cabinet of the machine and there are no lights/LED's or anything on the power supply (PW-SF) nor on the FR-SF drive. Any idea where to look would be great. Chips would get in the saddle and cut the wires . I get Alarm 20 NMI emergency stop and Alarm 204 Spindle controller malfunction. Within our spare parts department, Mazak globally retains nearly 195,000 part numbers in stock with more than $450 million in replacement parts and unit inventories for fast delivery. (C) CV Laser CO2 Tubes, Diodes, RF and Power Supplies; P2X4A. Feb 22, 2015 · I'm not sure how the transformer works on a Mazak, but have you checked to make sure it's properly tapped for 208v? You guys have 50Hz supply in South Africa, right? Make sure the shop you got it from wasn't running something different than your location. Description The signal from the chuck open/close foot switch has been input during chuck open/close command (M6, M7) in the automatic operation. AF2 or AF3 fuse blown. T. If the operator performs operations without being aware of data errors, Nov 3, 2021 · Batteries will be behind small doors (if the drives/power supplies have them) near the top of the unitsthe "red circles" above. I was getting these errors before when doing synchronous rotation during parting-off operations but now I'm getting them just doing normal roughing (Bar Out) on the sub-spindle. US $25. The main contactor seems fine and is showing open circuit when it should. but Jun 27, 2018 · Laser CO2 Tubes, Diodes, RF and Power Supplies; P2X4A. HEIDENHAIN Forum - HEIDENHAIN develops and manufactures linear encoders, angle encoder, rotary encoders, and CNC controls for rigorous positioning tasks. Category overview ; List of all discussion forums ; The 100 latest forum topics ; IndustryArena. Machine goes into E stop and can not clear it (control power/main disconnect off then on) like what we had last week. If anyone has it or could do a step by step guide I'd be very grateful. New and popular video trends Apr 29, 2021 · I hope that I am not repeating a question that has already been asked, but after spending several hours reading different post on this subject, I am still a bit stumped. See the description of No. Detected that the 3-phase input has an open phase. etc. See if you have a red LED and a green LED on. Power-to-X-for-Applications; Other Machines. Then after that it shows 'n' which means 'Power module overheat'. Mazak Alarm 376 MAIN POWER TURNING OFF MALFUNCTION Description When the front door of a CE specifications machine was opened with the setup key switch set to “O”, the electromagnetic… Mazak Alarm 375 MOTOR & SERVO TURNING OFF ERR. 2. I looked in the electrical cabinet and when it's started initially all the drives LED's appear correct (i. this is the alarm on mazatrol controller 21 Drive unit power malfunction 1,0,&0023 alarm the new spindle amp is flashing F6 and 23 we had this alarm before and was told to replace these two things. If the voltage exceeds 253 VAC (for the 200V system) or 530 VAC (for the 400V system), improve the power supply impedance. Detected that the 3-phase input to the main circuit of the PSM has an open phase. Shortage of P)wer supply capacity caused the power supply voltage to dro at start. Any advise on this would be much appreciated. I Aug 7, 2013 · On the back, PS EMG and BAT ALM lights are on, but the voltages of the power supply are fine (as far as I've checked). I believe it thinks the door remains open, and a couple guys believe it's the door parameter to the machine that needs to be changed? I'm still learning, but have you happened to run into a similar issue? Feb 4, 2016 · Join us! eMastercam - your online source for all things Mastercam. Bill . Other Machine Topics; CNC Wire Foam Cutter Machines; Digitizing and Laser Digitizing; Engraving Machines; Machine Created Art; Printing, Scanners, Vinyl cutting and Plotters; PCB milling; Commercial Products / Manufacturers Support Forums Jan 10, 2009 · Mar 25, 2024; Mazak; Replies 0 Views 403. Also for: Vtc-200c, Vtc-300c. Refer to the Mazak Manuals for detailed information on specific alarm codes; Identify the recommended troubleshooting steps and follow them carefully; Tip 2: Regular Maintenance. Oct 9, 2017 · Hello, I’m make some tests, this model don’t have capacitor, I check the vintage, AC 175V or DC 338V, I don’t have motor tag, I don’t know if is DC or AC! But in two ways have power. : X/B Drive :Flashes between d1 & d4 . When I looked at the alarm history, it also had a 204 spindle controller malf. Dec 3, 2010 · I can go through the motions of restoring the Abs Position and everything seems to go right. I have already tried the book solution of switch off and restart. 34 Servo malfunction 3 (&0000006F, &0008, ) Feb 22, 2008 · "378 Battery Malfunction (Turret)" So I managed to change the battery in the MR2J drive after watching a video of someone doing similar. ) but after a few minutes the main spindle drive LEDs go Dec 16, 2001 · 640 fusion and newer, one on the left side of the CNC chassis (behind the display) on the power supply board. The battery could be dead, we didn't check that, but that shouldn't be the reason why the machine wont boot up, I guess. Other Machine Topics; CNC Wire Foam Cutter Machines; Digitizing and Laser Digitizing; Engraving Machines; Machine Created Art; Printing, Scanners, Vinyl cutting and Plotters; PCB milling; Commercial Products / Manufacturers Support Forums started by QT-35 Mazak lathe with T-Plus controller ser# 130820 machine controller would not power up, we replaced QX141 and machine powered up, we lost parameters so initializing the machine, I copied from EEPROM, from what I remembered was never saved to and we did not have the org. Your battery alarm is probably something like the turret-index, or tailstock/sub-spindle drives. Action Require Mazak Technical Center or Technology Center to re-set the spindle parameters. The work of a PSU is to convert AC into DC before supplying it to the motherboard. I do see the W axis is counting movement without this axis moving. Nov 11, 2018 · 1. 3) Alarm S52 does not always mean an axis Mazak has a bunch of internal procedure write ups on this subject, which the factory guys use so much they have it memorized! PS - I know of one former Mazak guy that got his hand seriously hurt when he was called in to fix a stuck tool changer. This started making shorts in the system causing all kinds of alarms . This can't be good. Cause The servo (power-off level) is abnormal. NC led stays counts to 9, and just stays there. Aug 31, 2022 · See 1st part at https://youtu. PR ] or [6C MAIN CIRCUIT ERROR The main circuit capacitor in the power supply could not be charged correctly. Mar 25, 2024. Attached Thumbnails. But this is an amateur speaking!! Mar 5, 2018 · U2 - (Malfunction due to power supply voltage) generally the chiller lost main power or the main control board is bad A6 - (DC fan stop) Fan other or main board In the case where an oil cooler system is sent in, it is inspected and quoted for the estimated cost of repair. Dec 6, 2022 · I recently had a situation where my 3PH power supply had an arc happen at the bus bar/circuit breaker connection when I turned on the main power switch on my QT-15 /CAM-2. 2) Alarm Y06 is usually a parameter issue, and alarm Y03 with EMERGENCY STOP LIN may mean no CPU communication with amplifiers. To prevent malfunction, avoid bundling power lines (input/output) and signal cables of the servo Jan 17, 2019 · Mazak alarm cancel la alineó en la que no trae flecha y después la mando a casa y se ilumina que ya esta en casa pongo el bit 7 a 1 apago y prendo la maquina y me aparece la alarma intento mandar de nuevo a casa y no la toma ya revise la batería y trae 3. 6, 06. %PDF-1. 1) The power cable from the factory feeder switch to the machine main circuit breaker should have a sufficient sectional area to handle the electric power used. But when I power down and power up again I am back to square 1. Jul 3, 2019 · 42 SPINDLE PARAMETER MALFUNCTION Cause The parameters that have been transferred from the NC unit to the spindle amplifier during NC power-on are not correct. Please see attachment for the alarm. It has been throwing a alarm 21, power unit drive malfunction. Check the input power voltage as well as the voltage changes during motor deceleration. Recently, some of the machines had servo problem and need to repair. VTC-200B industrial equipment pdf manual download. Mar 12, 2013 · Well we have a new one today, #15 system Malfunction. Power back up and the alarm would be gone. 00: Jul 18, 2015 · started by QT-35 Mazak lathe with T-Plus controller ser# 130820 machine controller would not power up, we replaced QX141 and machine powered up, we lost parameters so initializing the machine, I copied from EEPROM, from what I remembered was never saved to and we did not have the org. I followed the procedure from the Mazak Bulletin No. 4. These horizontal turning centers and vertical machining centers place Mazak quality and reliability within reach for virtually any shop. the mitsubishi inside is having issues with bad hard drives or power supplies on the internal computer getting old and dying. This is the CPU board of the NC. Other Machine Topics; CNC Wire Foam Cutter Machines; Digitizing and Laser Digitizing; Engraving Machines; Machine Created Art; Printing, Scanners, Vinyl cutting and Plotters; PCB milling; Commercial Products / Manufacturers Support Forums Nov 22, 2021 · I have a Mazak QT 200 and I am getting a battery malfunction alarm after I have replaced batteries and checked parameters are in but I am still getting #8 battery malfunction alarm have checked batteries with a tester Hello. Had all kinds of problems with the wiring harness . but I think the old spindle amp was flashing F6 and 32 can anyone give some input on this? Jan 16, 2006 · Thinking back, the malfunction could have been cooking for a while, it happen at times that the 20NMI alarm would display at power-up and after powering down and up once or twice the alarm disappeared, and as not being persistent, I did not think much of it, and never went to the Diagnostic screen. [6C C MAIN CIRCUIT ERROR The buss is short circuited, the charge to the main CIRCUIT IS ABNORMAL. After I restore the abs zero I think I need to jog the spindle but I cant do this because of the it+ and it-. Sub Spindle Drive: r0 . While taking photos of all the jumpers on the boards, In better light I've discovered something very suspicious on the SR-CA board which looks like heat damage possibly from a short with a component on the board itself. Any ideas as to which components the alarm is referencing? Also, this happened during a cycle, not at power up as the alarm indicates. Main spindle Drive r0. Anything I can do or wait for Mazak service to fix it? Thanks 1. There is a persistent code, 304 (F104) ATC Arm Position Malfunction, that the operating manual describes as coming in when the ATC is stopped outside of its intended position and/or the cycle has not completed after +10 seconds from when the control Apr 25, 2022 · We have noticed the controls are getting old and will have random issues. Also check for an led on the main card LX51. I looked it up in the book and it said "The absolute position detection system has detected its detector error(s)". jb xp ie dr af ni mc sh ay ys