Klicky probe calibrate. For our machines, a range of 0.

Run a CALIBRATE_Z. Oct 15, 2022 · klicky-probe. klicky-variables (1). # This macro was provided by discord user Garrettwp to whom i give my thanks for sharing it with me. Nov 19, 2021 · [z_calibration] probe_nozzle_x: 271. I have it setup and running but I can't get the distance correct. For our machines, a range of 0. Even though my probe is definitely over the bed. Getting the z offset right is the main reason I'd want it. 3x 6 mm x 3 mm magnets. Code:PROBE_CALIBRATETESTZ Z=Further reading: https://www. Otherwise the optional parameters default to their equivalent setting in the probe config section. Or maybe just to store one and use on startup. Klipper plugin for self-calibrating z-offset. There are 2 types of movement modes for 3d printers. Read on to learn all about how it's done! In Klipper, Z offset calibration is a basic but important procedure. 2 x 20cm 22AWG cable to connect the Klicky Probe to the Mircofit Terminal. org/Bed Apr 25, 2023 · Set the switch_offset to any value greater 0. 8 i can't find a decent looking dock for the probe. My setup is as follows, zerog mercury, with klicky. Klicky Bed Mesh Calibration. I wasn't sure exactly what did, even after reading the docs. Microswitch probe with magnetic attachment, primarily aimed at CoreXY 3d printers. Los comandos son:PROBE_CALIBRATE (Inductivo / BLTouch / Klicky / QuickDraw / Etc)Z_ENDSTOP_CALIB Automatically adjusts to any buildplate material and thickness. 500 is z=4. Apr 10, 2022 · I like to switch flexible bed plates on my Voron 2. For the Front cowling mount assembly you need the following parts. To use it you must have a Z probe (BL Touch, Inductive sensor, etc). The Klicky Probe pin is PG15 and the Z endstop is endstop_pin: probe:z_virtual_endstop. # # this macro is based on the great Annex magprobe dockable probe macros "#Originally developed by Mental Klicky probe (there are three versions, all are interchangeable and compatible, more information on the specific printer page), what actually is used to probe the bed; Probe dock (all the printers use the same) Probe dock mount (what attaches to the printer to dock the probe when not in use) The CAD with all the files is located Here Sync the Klipper_macros folder of Klicky-Probe. The highly accurate, magneticaly coupled Z-Probe that is not affected by bed temp, bed material, magnetism or surface treatment. Here is an example of a failure : Move out of range: 165. Klicky带上自动Z_calibrating,换头换打印平台再也不用做Z偏移校准,下一步自动清洁。 视频演示使用Klicky后4轴调平-自动Z偏移-网床全过程。 边学边玩边造 Initial Startup Checks. Hi, guys. For Euclid it includes a macro that overwrites/renames QGL to specific for pickup and stowing the probe. 8 looks promising. cfg, bed mesh helper scripts, assumes bed mesh is already configured, includes a commented example, further help on setup here Make sure you have the latest klicky-macros. Sometimes 0. log (3. Contribute to AdamYellen/Klicky-Probe-macros development by creating an account on GitHub. 打印/制作klicky probe 2. The probe-specific pin is defined with Z_MIN_PROBE_PIN. If i press Bed_Mesh_Calibrate, the toolhead pic… Adaptation of the Klicky / Quickdraw Probe for the Ender 3 and comparable Creality printers. with the magnets and front secure, joint the mount front and back with an m2 screw Now, complete with the remaining two m2 screws that will keep the front level Attach another magnet on the 3rd probe magnet Stowable Probes. For klicky it may just be in separate config files from what I've seen. My printer config was originally done by someone else. klicky-probe. Once the underlying issue is corrected, use the “RESTART” command to reload the config and restart the host software. It always fails with “Probe samples exceed tolerance”. The klipper macros are here, the RRF here. There is a contact point between the screw and the wire. two wires to connect the controller to the extruder motor vicinity. 0的过程中处理z偏移校准的过程,以下均假设使用的配置为z_calibration附带,如果是原版klicky probe配置思路仍然适用,细节请视情况自行做调整。. need help with autoz calibration. Many probes are susceptible to "drift", ie: inaccuracies in probing introduced by heat or interference. Here you will find the necessary files and documentation to print and setup your own klicky probe on the Switchwire (finally). Set this to True if your machine has a probe that needs to be attached with a special macro before probing the bed. The probe can be configured to be used as Z-endstop, be manually or automatically deployed via gcode macros, and can take advantage of the firmware's probe pickup detection scheme to ensure pickup/release. Common Klicky STL's (parts that are common to all the printers) are located here. Repeatability check¶ After calibrating the probe X, Y, and Z offsets it is a good idea to verify that the probe provides Put two magnets on top on the probe front magnets Insert the correct front mount on the magnets so that they remain attracted to the probe. attach_macro: Define the macro that your machine uses to attach the probe here. So I run calibrate_z command and saved the new offset value. Super Glue. I made home xyz , then probe_calibrate comand then TESTz z= I can lower the Z on some mm but before the nozzle barely touch the bed I receive the error No trigger on probe after full movement. Doing Homing of all axis no errors occur. 4 R2 with Klicky Proble. Z_ENDSTOP_SERVO_NR So, YES, do agree that I would love to see Klicky as the default/stock probe with a beefier holder. 8, Trident, V0) and derivatives, now it's been restructured to better allow other printers to be documented here. What kind of probe do you have? FIX_MOUNTED_PROBE. somehow the calculation leads to a value of Z below zero. 0 is a good default value speed: 50 probing_first_fast: true start_gcode: ATTACH_PROBE #this is what you miss end_gcode: DOCK Oct 28, 2023 · That's an easy fixm either comment out this include " [include . 4x 6 mm x 3 mm magnets. 0025 is acceptable. cfg. Reply reply. Easy to set up. One may set the stepper_z endstop_pin to this virtual pin on cartesian style printers that use the probe in place of a z endstop. Those thinking about going with the TAP should think again! Dec 30, 2022 · The Klicky probe mod for Voron 2. cfg]" on klicky-probe. 2 x 18cm 22AWG cable to connect the Klicky Probe to the Microfit Terminal (if it turn out it’s too big, can always cut to lenght) Multimeter to check for Continuity. detach_macro: Define the macro that your machine uses to detach the probe here. Z endstop calibration tells you how much up or down toolhead needs to go from the moment Z endstop is It can also be used with the automatic Z calibration klipper plugin to effectively calculate the Z offset from the probe and from the Z endstop if your printers supports a Z endstop triggered by the nozzle (like most Voron’s do) Sep 27, 2023 · installing the klicky mod, when downloading the klicky-macros. 2%. I have attached the printer config file. 1 Klicky Probe做bed mesh calibration的视频,有网友咨询具体细节,昨天上传了视频版的安装与配置,今天配套上传一个文字精简版,供大家参考。 Jun 3, 2024 · Setup guide. cfg d) copy the content and paste them into the klicky-z-calibration. 4 yesterday and I'm having trouble with it. Today I had to stop printing at the 1st layer because nozzle is too close so the printed layer got pressed. I have a Switchwire with a docking magprobe on a servo arm. 7 #see the picture attached below probe_switch_y: 331. zip (9. In Klipper, Z offset calibration is a basic but important procedure. log Oct 4, 2023 · Probe calibrate tells you how high or low does toolhead need to move up or down with the nozzle to get optimal print height - from the moment probe triggered (inductive detected metal, Tap interrupted light beam, Klicky clicked on surface). to join this conversation on GitHub . 4 MB) If the results of PROBE_CALIBRATE are invalidated, then any previous bed mesh results that were obtained using the probe are also invalidated - it will be necessary to rerun BED_MESH_CALIBRATE after recalibrating the probe. by Andreas Giencke. This section provides a list of steps to help confirm the pin settings in the Klipper printer. 7mm. The default for the value for the endstop position is -0. If you are doing relative movement and send the x15 y15 z15 it will move 15 in the x direct 15 in the y and 15 in the z. Oh and bed mesh is a rocket compared to TAP since it never touches the BED. Be sure to issue a RESTART command after every change to the config file to ensure that the change takes effect (type “restart” in TThis is a Tiny-M 3D printer using a Klicky probe https://github. Place a piece of blue painters tape (or similar) on the bed underneath the probe. Shell 17. 0 (for example: 0. But for some reason, the very first calibration is always way off -- often it thinks the calculated offset is 0, or negative numbers. Doing QGL, Probe_Calibrate or Probe_Accuracy, all OK. Their github should have the proper macros and macro overwrites. The cost of the probe is <10€, of which the switch is the most expensive part. I had my printer all set up to print, then decided to add klippain plugin/macros. I can home all axis, I can z tilt, but when I do calibrate_z, it gets the nozzle about . Warning: When implementing 3rd party macros, pay particular attention to any variables that reference things like Z-Travel height or Z moves after probing or probe pickup. com/protoloft/klipper_z_calibrationAutomatic Z offset calibration Python 82. 002mm variation. Then, run the CALCULATE_SWITCH_OFFSET. Adjusting bed leveling screws using the bed probe¶ This is another way to calibrate the bed level using the bed probe. This can make calculating the probe's z-offset challenging, particularly at different bed temperatures. The Probe uses an internal magnet on top of the pin/stalk. It is labeled as position_endstop and can be found in the [stepper_z] section of the configuration file. Navigate to the OctoPrint “Terminal” tab and issue a PROBE Probe dock mount (what attaches to the printer to dock the probe when not in use) The CAD with all the files is located Here. 112500. This allows the unklicky to be normally closed. For anybody who needs a [homing_override], the following example has proven extremely reliably on a V0. com/jlas1/Klicky-Probehttps://github. # That macro as since evolved into a klipper plugin that currently is pending inclusion in klipper, I had this exact same problem on my Trident. If everything is correct, it will print an estimated switch offset. Jul 21, 2022 · You need to create a macro and use the rename existing option so it loads the probe before, and docks the probe after. This is the console output: 12:24 PM Probe samples exceed tolerance Apr 2, 2019 · The initial probe works fine but when I run the calibrate its not lifting away from the bed enough between probe poi I&#39;m sure I&#39;m missing something here. I am unable to probe calibrate my bltouch . cfg ,存儲所有 Klicky 變量,特定於打印機,不需要經常更新 klicky-bed-mesh-calibrate. 50 #d2f, read the docs max_deviation: 1. This command will run the probe ten times and produce output similar to the following: Recv: // probe accuracy: at X:0. # use, specify the coordinates of the switch here (Voron). As such, some printers use an endstop for homing the Z axis and a probe for calibrating the mesh. just wondering if this is already possible to do? (the user of klicky probe when doing AXIS_TWIST_COMPENSATION_CALIBRATE) is it possible to do the following steps. klack-probe. 5) Restart the Klipper firmware. The real part of the probing is actually done by the screw. 4 R2 replaces the inductive probe. My probe doesn't have any wild offset values in my config: [probe] pin: PG11. We would like to show you a description here but the site won’t allow us. 0 and higher has support for Stowable Probes. Just my z offset seems a bit off, the nozzle is a smidge too high. speed: 400 horizontal_move_z: 1 retries: 5 retry_tolerance: 0. I installed automatic Z calibration macro to my Voron 2. 4, but hate adjusting the printer's Z Offset. cfg file. cfg file, I encountered this problem. Reduced diameter from 5mm to 4. 4, V1. 5 or so away from the z endstop , then says "no trigger on prove after Saved searches Use saved searches to filter your results more quickly Separate axis probe counts - if print area X or y is 50% than available area, probe_count for that axis is changed from the default to 3; Supports Bed Mesh Relative Reference Index - if "relative_reference_index" is set in bed_mesh, it will be reconfigured to use the middle point on the bed; Klicky Probe Compatible - Works with Klicky Probe on klicky-probe. " klippy. You signed in with another tab or window. cfg ,床網幫助腳本,假設床網已經配置,包括一個註釋範例,在 此處設置更多幫助 Oct 1, 2021 · Using klicky as z-endstop. jlas1 self-assigned this Oct 28, 2023. # I have tweaked it a lot. 4 with Klicky Probe. 223 SWITCH=10. 0 #1. This magnet is not part of the circuit it is only used to provide a spring for the the probe. cfg in Mainsail c) go to Klicky github, in Klicky macros, click on klicky-z-calibration. The probe mount wires are also connected with pressure from the magnets, you can use the probe magnets as a template to insert the probe mount By default, 10 SAMPLES are taken. History. In this example, the Front cowling mount will be used. Micro switch only has two wires. I am trying to get my printer to do a bed mesh calibration on print start. NOZZLE_AS_PROBE. You are in the wrong mode after calibrating your esteps which Nov 7, 2023 · See the macro examples BED_MESH_CALIBRATE_ORIGINAL and HOME_LVL_MESH macros for recommendations. RatOS 2. Move the nozzle to the center of the bed and perform a manual Z offset calibration by moving the nozzle down, step by step, until it barely touches the print surface. * (Cura slicer plugin) To make the macro to work in Cura slicer, you need to install the post process plugin click here to download (based Jan 22, 2022 · HI guys . cfg, stores all the Klicky variables, printer specific, should not be necessary to update very often; klicky-bed-mesh-calibrate. Using Euclid, not klicky, but generally the same. cfg, bed mesh helper scripts, assumes bed mesh is already configured, includes a commented example, further help on setup here Jan 26, 2023 · I did forget to run PROBE_CALIBRATE and broke a piece right off of my carriage as my toolhead Sometimes PCB klicky probe is unreliable. conf and delete the cloned repository: rm -r ~ /klipper_z_calibration Toggle table of contents Pages 10 Now the will to change to a klicky probe is here looking forward to use klipper_z_calibration Plugin. 005 is z=2. I did see one thread somewhere but can't remember where and they were talking about having issues with probe positioning when the default printer acceleration was very high (the answer was some relatively undocumented klicky setting to limit acceleration for probe movements). Code. Existing command ‘PROBE_CALIBRATE’ not found in gcode_macro rename. com/jlas1/Klicky-Probe to calculate the Z offset automatically using klipper auto Z https:// Nov 4, 2023 · The BED gets much better leveling numbers now. cfg (includes all the necessary files in klipper) klick-variables. Preset includes exists for euclid, klicky and unclicky at the time of writing. The probe is compatible with Marlin and Klipper. cfg or configure klipper bed mesh. I noticed bed mesh clear is in my G32 and bedMesh load is commented out of start. You signed out in another tab or window. The probe section also creates a virtual "probe:z_virtual_endstop" pin. 003,0. Automatically adjusts to any buildplate material and thickness. Contribute to protoloft/klipper_z_calibration development by creating an account on GitHub. Recv: // and read 10 times with speed of 5 mm/s. The_cooler_ArcSmith. 0的probe,过程不再赘述。. May 18, 2022 · Hey guy! Its Jprince (GoldenJaguar392) In Today's video I'm doing a continuation of setting the klicky probe, In this specific video we are setting up Auto Z Calibration for kilcky Probe. Initially it was focused on the Voron printers (V2. 200 -0. Navigate to the OctoPrint "Terminal" tab and issue a PROBE command Sep 17, 2021 · General Discussion. Usually less than 0. cfg file that Klipper reads. Run the CALCULATE_SWITCH_OFFSET. Jun 17, 2024 · Basic Information: config-20240614-080751. The probe is compatible with all printers that use the X plate of the Ender 3. I am currently trying to perform the probe_calibrate. The objectives for this project are: Most of the Klicky probe users are using To calibrate the X and Y offset, navigate to the OctoPrint "Control" tab, home the printer, and then use the OctoPrint jogging buttons to move the head to a position near the center of the bed. 5 #your endstop x pos probe_nozzle_y: 353 #your endstop y pos probe_switch_x: 265. Already have an account? Apr 28, 2023 · You need to remove the [z_calibration] configuration from Klipper, the [update_manager z_calibration] block from the moonraker. (1) Add the following macro to your printer config, this will replace the default BED_MESH_CALIBRATE command. PROBE_CALIBRATE ===> to calibrate the distance between nozzle and klicky probe, just usual; BED_MESH_CALIBRATE ===> to probe the bed with the points defined and make a mesh to print better. With absolute movement if you tell it to go to x15 y15 z 15, it will move to x15 y15 z15 in the printer area. To enable this feature, one would determine the nozzle coordinates such that the Z probe is above the screws, and then add them to the config file. probe location with klicky; dock probe; go back to the probed location; adjust Z offset; after click accept, it will then go and pick up probe again and go to the next location PROBE_ACCURACY ===> to test the accuracy of our probe, look at the range exit. Aug 4, 2023 · En este video veremos como calibrar el Z Offset en Klipper. Klicky Probe. 0075 max_adjust: 10. 之前发了个Voron 0. org/https://www. Use this option if the nozzle itself is used as the probe. Homing, QGL and bed mesh complete without any errors. 506948. cfg, stores all the Klicky variables, printer specific, should not be necessary to update very often; klack-bed-mesh-calibrate. If you use a stowable probe that doesn't have a preset, you can use any one of the presets as a template, just copy the To calibrate the X and Y offset, navigate to the OctoPrint “Control” tab, home the printer, and then use the OctoPrint jogging buttons to move the head to a position near the center of the bed. As cool as it is to get faster benchy's and multiple filaments, I just want the thing to work on it's own as much as possible. In my 1st build, I install Klicky to avoid the inductive probe issue which could melt late My guess this is happing if you have done BED_MESH_CALIBRATION ( my bed is not level at all). zip Whenever I run a PROBE_ACCURACY or PROBE_CALIBRATE I get the following error: Must perform … with the probe above the BED! …. The probe is compatible with all printers that use the X plate of the Ender 3 and cost of the probe is <10€, of which the switch is the most expensive part. 9 KB) When manually triggering the Klicky Probe; both the Klicky Probe and the Z endstop trigger together. klipper3d. I’m wondering if this is because it’s not probing the middle of Navigate to the OctoPrint terminal tab and run the PROBE_ACCURACY command. In my guess, there must be my mis-configuration. Probe Type. Jul 28, 2021 · A quick guide on setting your probes Z offset in Klipper. See the PROBE command for details on the optional probe parameters. Now I have a big divot in the magnet bed to remind me. cfg (includes all the necessary files in klipper) klack-variables. Without the probe, move the nozzle to the center of the bed and perform a manual Z offset calibration by moving the nozzle down, step by step, until it barely touches the print surface. 300, when it should start to print i get a &quot;horizontal_move_z can&#39;t be less than probe&#39;s z_offset&quot; 😭 any su # They are based on the great Annex magprobe dockable probe macros "#Originally developed by Mental, # modified for better use on K-series printers by RyanG and Trails", kudos to them. 000. If you run Klipper on your 3D Klicky Probe for Vorondesign Switchwire printers. /klicky-bed-mesh-calibrate. cfg in Mainsail e) enter the values that you have for your Step 3: Probe mount Assembly. 500,142. I do a probe_calibrate, set the z_offset = 7. 000 Z:10. I have bl touch setup and everything seems to be in order, my offsets seem to be very similar to other Ender 3 V2 users, and the BED_MESH_CALIBRATE command seems to probe the correct spots. I am getting the message "Probe triggered prior to movement" after I enter probe_calibrate into the console. 但应该选用触发压力小的微动(软的 Nov 27, 2022 · The only way I have ever successfully done a Z home is by manually homing X and Y, then manually attaching the probe (which required me to reset polarity of the probe endstop pin (which now shows as normally triggered) and running the Z home. That does make sense, just limit how much movement there is on Z. cfg, and then you can skip the rest of this guide; you’re done here! If you already have a [homing_override] and you’re not using Klicky, replace G28 X with _HOME_X and replace G28 Y with _HOME_Y. I'm using Tap now also. cfg and replace them with the position of my z endstop switch. 3 KB. 5 as a safety factor to prevent crashing the nozzle into the print surface during initial operations. 185 --> OFFSET=-1. When manually triggering the Z endstop, nothing happens. May 8, 2020 · But in short, I try to run the Z_ENDSTOP_CALIBRATE, move it up and down a bit with testz, but when I accept, it says: "Manual probe failed! Use TESTZ commands to position the nozzle prior to running ACCEPT. Probe accuracy Apr 5, 2023 · Klipper: Z Offset Calibration – Simply Explained. 总结一下从klicky probe 1. Printer is halted klippy (1). You only need to calibrate one variable: Nozzle-to-switch offset distance, instead of Z-endstop pin and switch body and nozzle. x_offset: 0. If I add a bed_mesh_calibrate in G32 after Quad_gantry Also, see the probe calibrate guide. Mar 10, 2024 · On an LDO Voron 2. Printer specific STL are in each printer directory. cfg, bed mesh helper scripts, assumes bed mesh is already configured, includes a commented example, further help on setup here . Both firmwares work with the G29 command, the Oct 17, 2022 · Edit 30 Jun 22 - Tightened tolerances for heatset insert holes for both E5/Pro and E5 Plus models. If using "probe:z_virtual_endstop" then do not define a position_endstop in the stepper_z config section. I moved all my cfg info from before into the respective places. Most boards have a default, but it can be overriden in the configuration. I had set mine to almost minus one millimeter. lord-carlos; Oct 17, 2023; Jul 13, 2022 · V2. Nov 20, 2023 · Topic: I’d like support for dockable probes for the new axis_twist_compensation feature. Separate axis probe counts - if print area X or y is 50% than available area, probe_count for that axis is changed from the default to 3; Supports Bed Mesh Relative Reference Index - if "relative_reference_index" is set in bed_mesh, it will be reconfigured to use the middle point on the bed; Klicky Probe Compatible - Works with Klicky Probe on EUCLID PROBE. Published Apr 5, 2023. 607 lines (507 loc) · 19. I have all of the movement down it probes when I go to test distance from bed the only way I have been able to make the offset move is be changing the z endstop position. 0升级到2. 000mm. Recv: // probe at -0. I’m running out of “easy” hardware fixes that could be causing inaccuracy between a bed mesh and the actual first layer squish (parts of the bed have too much squish and other parts have too little after doing a heat soak, clear bed mesh, G28, QGL, G28 Z and bed mesh calibrate) and it sounds like Feb 17, 2022 · b) use create a file (the icon that has a + sign on a file or 2nd icon from the left at the top) and call it klicky-z-calibration. 242 PROBE=7. I found that I had forgot to comment out the "0,0" settings for the x,y z endstop position in klicky-variables. I&#39;m trying to run bed_mesh_calibrate on my AM8 (fitted with a capacitive z sensor). So quickdraw would be a nice drop-in and everything seems easy, but vor my Voron 1. To use one of the presets, you need to uncomment it in your printer. Feb 8, 2023 · Just got home, I use TAP so this is fine for me but if you use Klicky try and get it 1 or 2 mm above the bed. 8%. The arm drops down and probes like it should and gives me the following: I have done the followig: probe at 161. Never got less than . 313 85. Must be some weird probe off-set thing. Benefits. Dec 20, 2022 · The reference to "switch offset" implies @Laserbea4k43 is using a klicky probe mod, it's well worth checking out! Combined with auto_z when working correctly first layers are a breeze! Combined with auto_z when working correctly first layers are a breeze! Navigate to the OctoPrint terminal tab and run the PROBE_ACCURACY command. (2) Go to slicer setting and replace the old bed mesh gcode the following command. 531 you can work around this by setting the following to negative value. PROBE_CALIBRATE¶ PROBE_CALIBRATE [SPEED=<speed>] [<probe_parameter>=<value>]: Run a helper script useful for calibrating the probe's z_offset. On the other side Klicky-Probe looks quite similar and especially the dock for the Voron 1. Use this option for a fixed switch or inductive probe. 2. Getting the Klicky Probe to calibrate my Z Offset. Cannot retrieve latest commit at this time. 9 #see the picture attached below switch_offset: 0. cfg(包括 klipper 中所有必要的文件) klick-variables. Reload to refresh your session. You switched accounts on another tab or window. Edit 17 Oct 22 - Added mirrored versions for the Ender 5/Pro version for users who have done a dual Z mod (thanks for the request Roadrunnr!) Music: Quasimoto - Low Class Conspiracyhttps://github. When I run calibrate_z, the klicky probe is attached and then the probing with the nozzle to the z endstop starts. 010m with TAP. Here's an example of running it 3 times in a row: Z-CALIBRATION: ENDSTOP=2. It kinda works with a relative reference on the mesh so long as I ONLY print at one Sep 23, 2022 · I'm using protoloft's auto Z height code and I thought it's been working out. Read on to learn all about how it's done! Adaptation of the Klicky/Quickdraw Probe for the Ender 3 and comparable Creality printers. During this guide, it may be necessary to make changes to the Klipper config file. Both firmwares work with the G29 command, the The Z endstop position value is defined in the printer. Take a look at all the configuration files for klicky to see how this is done. It uses a slightly different approach than most magnetically attached probes, it's secured on the X extrusion, so it's available on any Z height and can be used without Jul 9, 2022 · Well I guess that's good news, we've eliminated the probe being faulty. 000 Y:0. •. It's a chore I don't enjoy. probe_dock_enable: By default, this setting is False. 230 NOZZLE=2. Docking and undocking klicky proble also ok. 1. xb zc iv jt iw nf bi cm jt yi  Banner